TitelLogo
High frequency analyser kit HFE59B

Gigahertz Solutions high frequency analyser kit HFE59B

  • The total exposure is being measured and displayed directly in the units of the recommended limiting values of the standard of building biology SBM (µW/m²)
  • The included logarithmic periodic antennas fully compensated and allow for pinpointing the source of EMF-pollution
  • The high resolution and long time precision is granted through also patented self-aligning circuitry elements
  • The audio analysis feature helps identifying the underlying radio services
  • The provided measurement guideline including their recommended limiting values of the standard of building biology SBM enables even technical laymen to perform a reliable assessment of the personal EMF-pollution, as well as a determination of suitable remedial actions, and a control of their effectiveness
  • Display of peak value as well as average value (switchable)

Manufacturer: Gigahertz Solutions - ManufacturerNr 530-054 / Art.Nr. 0404
Environment & Disposal

High frequency analyser kit HFE59B

This kit offers an excellent dynamic response of approx. 93 dB. The innovative functions of the basic device HF59B in combination with the broad frequency response of the UBB27 offers outstanding possibilities for the evaluation of high frequency. Its functions and features are tailored to the needs and practical experiences of the building biology. Due to its comparably low price, it is often also used for scientific and industrial purposes, especially in the sector of EMVU and product development (precompliance).


The total exposure is being measured and displayed directly in the units of the recommended limiting values of the standard of building biology SBM (µW/m²).

An acoustic signal proportional to the field strength with "Geiger-counter-effect" helps identifying regions with increased exposure.

Audio analyses for the identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control radar) by means of an acoustic signal proportional to the modulation frequency.
Digital display of 1 µW/m² up to 1999 µW/m².

Display of peak value as well as average value (switchable).

Sensitivity increased by a factor of 10 (from a minimum display resolution of 0.1µW/m² to a maximum of 1999 µW/m²).

The log.-per. antenna with further improved frequency response.

A 10 times higher sensitivity: Minimum display resolution 0.01 µW/m². A measuring range extended upwards by a factor of 10: max. 19.99 mW/m² .

Clearly simplified measurements with the help of the "peak-hold"- function.

A quantitative differentiation between pulsed and un-pulsed radiation - a unique feature within the broadband measuring technology (based on our patent DE10317805).

A switch for 2 MHz video bandwidth, allowing especially precise measurements, also of ultra short RADAR signals within the frequency range subject to measurement with a minimum pulse length of up to 0.5 micro seconds, as well as of UMTS-FDD/3G.

A frequency range of down to 27 MHz within the basic device - suitable for the connection of the optionally available antenna UBB27_G3 (the scope of delivery includes a compensated antenna for 800 MHz up to 2.7 or 3.3 GHz).

A calibrated extra AC-measurement output for the demodulated signal, and a scalable DC-output.